Ariston Kit C Unvented Water Heater Discharge Turndish
|
Shipping: £3.75 inc vat, To UK mainland. Are you subject to a Shipping Surcharge?
Spend Over £200 for Free Shipping
In Stock at Depots
|
Price: £11.87 inc vat
£9.89 ex vat
Product Code: 406807
|
The Ariston Kit C Unvented Water Heater Discharge Turndish if for use when it is not possible to accommodate the expansion in the system pipe work, it is then necessary to use a set of expansion controls. The discharge from relief valves must be made in a safe and conspicuous manner; therefore a Discharge Turndish (Kit C) is available for 10 and 15 litre units if required.
The following guidelines refer to Building Regulation G3. It is good practice to follow these guidlines for all relief valve discharge pipe work.
1) The tundish must be vertical and fitted within 500 mm of the temperature & pressure relief valve and must be located with the cylinder. The tundish must also be in a position visible to the occupants, and positioned away from any electrical devices. The discharge pipe from the tundish should terminate in a safe place where there is no risk to persons in the vicinity of the discharge and to be of metal.
2) The discharge pipe must have a vertical section of pipe at least 300 mm in length, below the tundish before any elbows or bends in the pipe work.
3) The discharge pipe must be installed with a continuous fall.
4) The discharge must be visible at both the tundish and the final point of discharge, but where this is not possible or practically difficult; there should be clear visibility at one or other of these locations. Examples of
acceptance are:
i) Ideally below a fixed grating and above the water seal in a trapped gully.
ii) Downward discharges at a low level; i.e. up to 100 mm above external surfaces such as car parks, hard standings, grassed areas etc. These are acceptable providing that where children may play or otherwise come into contact with discharges, a wire cage or similar guard is positioned to prevent contact, whilst maintaining visibility.
iii) Discharges at high level; i.e. into a metal hopper and metal down pipe with the end of the discharge pipe clearly visible (tundish visible or not). Or onto a roof capable of withstanding high temperature discharges of water 3m from any plastic guttering systems that would collect such a discharge (tundish visible).
iv) Where a single pipe serves a number of discharges, such as in blocks of flats, the number served should be limited to not more than 6 systems so that any installation can be traced reasonably easily. The single common discharge pipe should be at least one pipe size large than the largest individual discharge pipe to be connected. If unvented hot water storage systems are installed where discharges from safety devices may not be apparent i.e. in dwellings occupied by the blind, infirm or disabled people, consideration should be given to the installation of an electronically operated device to warn when discharge takes place. Note: The discharge will consist of scalding water and steam. Asphalt, roofing felt and nonmetallic rainwater goods may be damaged by such discharges.